Horizontal Type Quick-Opening Closure

Horizontal Type Quick-opening Closure is a kind of quick-opening Device which is installed on side of equipment and frequent opening position, with closure's cover open laterad.

Introduction

Brief Introduction

Horizontal Type Quick-opening Closure is a kind of quick-opening

Device which is installed on side of equipment and frequent opening position, with closure's cover open laterad. It is one of SH Series Quick Opening Closures with Clamp-ring which has horizontal type and vertical type (vertical type is installed on the top of equipment and frequent opening position, with closure's cover open vertically.) is our self-developed patented product which is designed and manufactured refer to the most advanced products abroad in 1990s, and the source of standard is SY/T0556-1999 PRC Trade Standard of Petroleum—Quick Opening Closure.

 

Horizontal Type Quick-Opening Closure Structural Drawing

            

 

Zhengzhou Wanda Mac-Global Development Co., Ltd.

 

Structural Drawing of Horizontal Quick-opening Closure

1.O-Ring 2. Safety Cardboard 3.Vent Valve 4.Cylindrical Pin  5.Screw 6. Jointed Shaft 7. Adjusted Nut 8. Pin Roll 9. O-sealing ring 10. Closure's Base 11.Clamp-ring 12.Closure's Cover

 

Open and Close Method of Closure

1. Opening Procedures

Open the vent valve and drain valve of the installation vessel of blind plate to decrease the inner pressure to zero. Special Tip: Not allow open it under pressure. Open the vent valve and drain valve of the installation vessel of blind plate to decrease the inner pressure to zero. Screw the core vent; take off the loose-proof pallet. Rotate the screw mandrel by special wrench according to the direction marked on switch to enlarge gradually the inner diameter of the three pedals locking until it is larger than the outer diameter of the blind cover and stop. At this time, the clamp collar is apart from the base and cover of blind. Pull the handle to the right side and open the blind plate.

2.  Closing Procedures

Clear up thoroughly the dirties in sealing surface, seal groove and clamp collar up and down, and paint grease to prevent from rust. Close and push tightly the blind plate. Rotate the screw mandrel anticlockwise by special wrench and compact the blind cover .Fit over the groove hole of the loose-proof pallet and position, screw down the core vent (Pay attention, the sealing ring shall not be dropped)

Ⅳ Safety Operation and maintenance

(1)When weld the blind plate and the barrel, the current shall not be too large. Pay attention that do not make the blind plate over heated to avoid distortion.

(2)People who use the blind plate must know the structure and the operation procedure well.

(3)Do open the vent valve before the blind cover is opened. Operation can be carried out only when the inner pressure of the pig receiver & launcher decreases to zero.

(4)Before adding pressure inside the receiver & launcher, do install the loose pallet well. And then it can be put into operation.

(5 )When the receiver & launcher is put into application, it is not allowed to knock or impact any main compression parts.

(6)The driving mechanism and the screw mandrel locking device of blind plate must be painted grease often to prevent from rust. And the appearance must be kept complete, bright and clean often.

(7)Inspect the main compression parts (e.g. blind cover, external surface of barrel) of blind plate regularly. Check causes for serious corrosion or cracks and process properly.

(8)Wash, inspect and paint grease on the sealing ring and the sealing groove after use in case they can not be sealed while operation.

(9)  Keep paint for closure's outer surface brightly integrity.

(10) Install the explosion proof switch of the fast opening blind plate with the goods in the blind plate(fix only the blot), when fast opening blind plate to open in place travel switch start. Install travel switch connected cable transmission, the travel switch is DPDT, can provide instant switch signal, voltage rating of 380V, current 2A, explosion-proof grade EXDIIBT4,protection levels to meet IP65. (The specific installation instructions see FIG.1)

 

FIG.1

Zhengzhou Wanda Mac-Global Development Co., Ltd.

Parameter

Fault Reason and Solution

1. Leakage in sealing ring.

A. Please clean then sealing groove, sealing surface and o-ring and then install the sealing ring.

B. Please exchange ageing sealing ring in time.

2. Leakage in Vent Valve

Using the same treatment method with provision 1.

3. Leakage in Safety Interlock.

Using the same treatment method with provision 1.

4. Leakage in Other Position

Please search and find leakage reason in time, and inform manufacturer. Manufacturer shall provide treatment scheme and deal with the leakage position. (Or licenses Process). Please do not deal with it privately, otherwise all the results is at your own risk

5. Please contact us if you cannot resolve the fault or problems according the introduction. We shall provide you relevant scheme within 1 workday; Under special condition, we shall send our staff to the site and deal with the them within 3 days